When changes are made to any of the residual stress measurement techniques that we perform in our laboratory, whether that’s a revision to a measurement standard or a change to the equipment we use, a thorough validation is performed to ensure the residual stress data we obtain using the updated measurement process meets Hill Engineering’s internal quality standards. A recent update to ASTM E837, Standard Test Method for Determining Residual Stresses by the Hole-Drilling Strain-Gage Method, prompted us to perform this validation.

ASTM E831-25e1 adds additional guidance for scenarios where the center of the drilled hole is not concentric with the strain gage circle. In cases where this radial eccentricity is outside of the acceptable range to be considered concentric, but less than the upper limit, a correction is applied to account for the increased and/or decreased strain signal at each strain gage of the rosette, which affects the final calculated residual stress. If the radial eccentricity is greater than the upper limit, the measurement cannot be corrected reliably and is discarded.
Hill Engineering performed both experimental and analytical analyses to confirm the calculations described in this latest revision of ASTM E837 produce the expected results and have begun to roll out updates to our internal procedures, DARTTM measurement software, and personnel training. We hope to continue to provide our customers with the high-quality residual stress data that Hill Engineering is known for, and updates to standards like this make that possible.
Are you interested in hole drilling residual stress measurements for your project? Contact us today.